Step 10
Put the cylinder on the base, and into the fixed
cylinder round.
bolts and tighten it in order to prevent the cylinder
from moving.
Warning:
The cylinder used must include a collar to protect
the cylinder valve.
Do not store a spare LP Gas cylinder under or near
this appliance.
Never fill the cylinder beyond 80 percent full.
For appliances designed to use a CGA No.791
connection: Place the dust cap on the cylinder valve
outlet whenever the cylinder is not in use. Only
install the type of dust cap on the cylinder valve that
is provided with the cylinder valve. Other types of
caps or plugs may result in leakage of propane.
Note:
Gas supply pressure: 25 to 250PSI
Step 11
Check for leaks
Your patio
heater has been checked at the factory
for all possible connection leaks. To check the
connection of the gas hose / regulator /cylinder:
1. Make leak solution by mixing 1 part liquid dish
soap and 3 parts water.
2. Spoon several drops(or use quirt bottle) of the
solution onto the gas hose /regulator and regulator
/cylinder connection.
3. Inspect the connections and look for bubbles.
4. If no bubbles appear, the connection is safe.
5. If bubbles appear, there is a leak. Loosen and
re-tighten this connection.
6. If leak continues, call a qualified service person.
7. Use of Teflon(plumbers)tape on threads of
gas
connections is recommended.
ASSEMBLY
Attach the cylinder to the base with 3pcs M8x12
Step 10
Step 11
12
Seitenansicht 11